{"product_id":"tigo-rsd-optmizer-22a-ts4-a-o-copy-1","title":"APSmart Rapid Shut Down Single (RSD-S-PLC)","description":"\u003cp\u003eThe APSmart Rapid Shut Down Single (RSD-S-PLC) delivers fast, reliable emergency shutdown capability for critical applications. This dual-input device enables quick system termination when needed, combining compact design with dependable performance. Ideal for safety-critical environments where rapid response is essential. Built for industrial and commercial use with straightforward integration into existing control systems.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: sans-serif; font-size: 14px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003cth style=\"text-align: left; padding: 10px 12px; border: 1px solid rgb(224, 224, 224); font-weight: 600; width: 100%;\" colspan=\"2\"\u003eAPsmart RSD-S-PLC - Rapid Shutdown Device Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eInput voltage range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e10.5 - 80 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eMax. continuous input current (Imax)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eMax. short-circuit current (Isc)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eMax. series fuse rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eOutput voltage range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e10.5 - 80 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eMax. system voltage (Vmax)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e1000 V \/ 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eCommunication protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003ePower Line Communication (PLC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eShutdown trigger\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eTransmitter signal absent or breaker switched off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eDimensions (without cable)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e5.5\" ? 1.3\" ? 0.7\" (140 ? 32 ? 18 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eNEMA 6P \/ IP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eConnector type (input)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eSt?ubli MC4 (PV-KBT4 \/ KST4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eCable length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eInput: 250 mm \/ Output: 1200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eCable cross-section\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003e-40 ?F to +185 ?F (-40 ?C to +85 ?C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eNEC compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eNEC 2017, 2020 \u0026amp; 2023 (Section 690.12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); color: rgb(85, 85, 85); width: 48.1216%;\"\u003eSafety standards\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px; border: 1px solid rgb(224, 224, 224); width: 51.8784%;\"\u003eUL 1741, CSA C22.2 No. 330-17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave any questions? Email us at info@solwel.com or give us a call at \u003ca data-dtype=\"d3ph\" data-local-attribute=\"d3ph\" href=\"https:\/\/www.google.com\/search?q=solwel+houston\u0026amp;rlz=1C1JSBI_enUS1093US1094\u0026amp;oq=solwel+houston\u0026amp;gs_lcrp=EgZjaHJvbWUqDggAEEUYJxg7GIAEGIoFMg4IABBFGCcYOxiABBiKBTIHCAEQABjvBTIKCAIQABiABBiiBDIKCAMQABiABBiiBDIKCAQQABiiBBiJBTIKCAUQABiABBiiBDIGCAYQRRg9MgYIBxBFGDzSAQg0NDIwajBqNKgCALACAQ\u0026amp;sourceid=chrome\u0026amp;ie=UTF-8#\" data-ved=\"2ahUKEwj70LmCwPCTAxUpxskDHUqWLYAQkAgoAHoECCIQAg\"\u003e\u003cspan aria-label=\"Call Phone Number (346) 432-4228\"\u003e(346) 432-4228\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eWhat is rapid shutdown and why is it required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eRapid shutdown (RSD) is an NEC code requirement that allows emergency responders to de-energize a solar array quickly and safely. It is required on most new residential and commercial installations in the US.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eIs this compatible with my inverter?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eCompatibility depends on your inverter and system configuration. Contact our team to confirm compatibility before purchasing.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003e\u003cstrong\u003eIs professional installation required?\u003c\/strong\u003e\u003c\/summary\u003e\u003cp\u003eYes - rapid shutdown devices must be installed by a licensed solar professional to ensure NEC compliance. Solwel offers Solwel can connect you with certified local installers in the Houston and Dallas area.\u003c\/p\u003e\u003c\/details\u003e","brand":"APS","offers":[{"title":"Default Title","offer_id":52550204064033,"sku":null,"price":37.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/1442\/5633\/files\/RSD.png?v=1779305361","url":"https:\/\/shop.solwel.com\/products\/tigo-rsd-optmizer-22a-ts4-a-o-copy-1","provider":"Solwel","version":"1.0","type":"link"}